概述
GenServer 的 terminate callback 在进程退出时会被调用.
但若没有:erlang.process_flag(:trap_exit, true), 进程可能被悄无声息地 kill 掉, 而不走 terminate 回调.
示例
App.Supervisor 下有一个 App.Worker, 代码如下.
defmodule App do
use Application
require Logger
def start(_type, _args) do
children = [%{id: App.Supervisor, start: {App.Supervisor, :start_link, []}, type: :supervisor}
]
opts = [strategy: :one_for_one, name: __MODULE__]
Supervisor.start_link(children, opts)
end
end
defmodule App.Supervisor do
use Supervisor
require Logger
def start_link() do
Logger.info("app.sup start")
Supervisor.start_link(__MODULE__, [], name: __MODULE__)
end
def init([]) do
children = [%{id: App.Worker, start: {App.Worker, :start_link, []}, type: :worker}
]
opts = [strategy: :one_for_one, name: __MODULE__]
Supervisor.init(children, opts)
end
end
defmodule App.Worker do
use GenServer
require Logger
require Record
Record.defrecordp(:state, [])
def start_link() do
Logger.info("app.worker start")
GenServer.start_link(__MODULE__, [], name: __MODULE__)
end
def init(_) do
# :erlang.process_flag(:trap_exit, true)
{:ok, nil}
end
def handle_call(:stop, _from, state) do
{:stop, nil, state}
end
def handle_call(:raise, _from, state) do
raise RuntimeError
{:reply, nil, state}
end
def terminate(reason, state) do
Logger.warn("app.worker terminate #{inspect(reason)} #{inspect(state)}")
:ok
end
end
没有 trap_exit
若没有:erlang.process_flag(:trap_exit, true).
- Supervisor.stop(App.Supervisor)
- Supervisor.terminate_child(App.Supervisor, App.Worker)
- Process.exit(:erlang.whereis(App.Worker), :normal)
均不会触发 terminate 回调.
- GenServer.call(App.Worker, :stop)
- GenServer.call(App.Worker, :raise)
会触发 terminate 回调.
有 trap_exit
- Supervisor.stop(App.Supervisor)
- Supervisor.terminate_child(App.Supervisor, App.Worker)
会触发 terminate 回调.
20:25:00.568 [warn] app.worker terminate :shutdown nil
- Process.exit(:erlang.whereis(App.Worker), :normal)
会收到 {:EXIT, #PID<0.149.0>, :normal} 消息, 若处理了消息, 不会触发 terminate 回调.
20:25:59.849 [warn] unknown_info:{:EXIT, #PID<0.134.0>, :normal}
- Process.exit(:erlang.whereis(App.Worker), :shutdown)
20:27:55.170 [warn] unknown_info:{:EXIT, #PID<0.134.0>, :shutdown}
- GenServer.call(App.Worker, :stop)
- GenServer.call(App.Worker, :raise)
会触发 terminate 回调.
总结
GenServer msg loop 中的逻辑, 不管是 stop, 还是异常 (很可能被捕获), 都会触发 terminate.
若没有 trap_exit, 收到 exit 消息时, 进程会直接被杀, 不会触发 terminate.
若有 trap_exit, 可以保证 terminate 被调用.
因为结果很合乎直觉, 就不看源码深究了.